Safety Ratings
Standards
IEC/EN61496 Parts 1 and 2, UL61496 Parts
1 and 2, UL1998
Safety Classification
Type 2 per IEC 61496, Category 2 device
per EN 954-1
Certifications
cULus, TÜV, and CE Marked for all
applicable directives
Power Supply
Input Power, Max. 24V DC ± 20%
Maximum Residual Ripple
< 10% of U
sp
Power Consumption <500 mA (no load)
Outputs
Safety Outputs 2 PNP OSSD. 0.3 A, short-circuit protected
Output Voltage, Min.
U
sp -1
Switching Current @ Voltage,
Min.
300 mA @ 24V DC
Operating Characteristics
Response Time Varies by protective height
Indicator LEDs ON -State, OFF-State, internal error
Protected Height [mm (in.)]
120…1920 mm (4.7…75.6 in.) in 120 mm
(4.7 in.) increments
Resolution [mm (in.)] 30 mm (1.18 in.)
Scanning Range 0…6 m (0…19.7 ft)
Synchronization Optical, first beam adjacent to LEDs
Wavelength 950 nm
Environmental
Enclosure Type Rating IP65
Relative Humidity 15…95% (noncondensing)
Operating Temperature [C (F)] 0…55 ° (0…131 °)
Vibration
IEC 60068-2-6 frequency 10…55 Hz;
amplitude 0.35 mm (0.01 in.)
Shock
IEC 60068-2-29; acceleration 10 g, pulse
duration 16 ms 10…55 Hz; amplitude
0.35 mm (0.01 in.)
Physical Characteristics
Mounting
Rear mounting, standard and adjustable
(180°)
Weight Varies by protective height
Housing Cross Section 30 x 40 mm (1.18 x 1.57 in.)
Connection Type
Transmitter: 5-pin M12 micro QD.
Receiver: 5-pin M12 micro QD
Cable Length
2, 5, 10, 15, 20, or 30 m (6.56, 16.4, 32.8,
49.2, 65.6, or 98.4 ft)
ILAS Laser Class Class 2, IEC 60825-1
Specifications
Applications
y M12 connectors
y Optically synchronized
y Integrated laser alignment system
y IP65 enclosure rating
y Simple Instalation
y cULus and CE Marked for all applicable directives
Features
ATTENTION: Safety light curtains of a Type 2 level of
safety typically do not meet OSHA or ANSI requirements
of “Control Reliability,” therefore it is not allowable to use
a safety device of a Type 2 level on or around equipment
or machinery that requires “Control Reliability.”
y Conveyors
y Textile machinery
y Automatic storage and retrieval machinery
y Automated assembly lines
The Allen-Bradley Guardmaster GuardShield Safe 2 safety light
curtain is a new addition to the ABGM portfolio of opto-electronic
safety devices. The “Type 2” designation means that this particular
safety light curtain meets a lesser requirement for performance
under fault conditions than the GuardShield Type 4 safety light
curtains. As a result, the GuardShield Type 2 safety light curtain can
only be applied in applications where a formal risk assessment has
determined that a Type 2 device is sufficient to meet the level of risk
posed by the hazard.
The GuardShield Safe 2 safety light curtain is a self-contained two-
box, safety light curtain in a robust housing with an integrated laser
alignment system. The integrated laser alignment system generates
two visible beams of light which simplifies alignment of the light
curtain pair.
This economical opto-electronic Type 2 safety light curtain is offered
in a guard only mode of operation and is designed for use on or
around machinery or equipment where a formal risk assessment has
determined that a Type 2 safety device is of a sufficient level of
safety to meet the guarding application.
Description