Allen-Bradley ControlLogix Manual do Utilizador Página 146

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 212
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 145
146 Rockwell Automation Publication 1756-UM001O-EN-P - October 2014
Chapter 9 Develop Motion Applications
If Jog_Pushbutton = on and the axis = on (My_Axis_X.ServoActionStatus = on) then the MAJ instruction jogs the axis forward at 8 units/second.
If Jog_Pushbutton = off then the MAS instruction stops the axis at 100 units/.second
2
. Make sure that Change Decel is Yes. Otherwise, the axis
decelerates at its maximum speed.
If Move_Command = on and the axis = on (My_Axis_X.ServoActionStatus = on) then the MAM instruction moves the axis. The axis moves to the
position of 10 units at 1 unit/second.
Vista de página 145
1 2 ... 141 142 143 144 145 146 147 148 149 150 151 ... 211 212

Comentários a estes Manuais

Sem comentários