Communication Setup (Cable Configuration) 4-25
Publication 2755-6.2
Baud Rate
Sets the rate (bits per second) at which the scanner transmits data. The
scanner baud rate setting must match the host setting. The selections are:
600
1200
2400
4800
9600 (default)
19200
Parity
Set the parity of each ASCII coded character that is transmitted. Make
sure the parity matches the requirements of the host. The selections are:
Odd
Even (default)
Mark (parity bit always set to 1)
Space (parity bit always set to 0)
None
Note: We recommend that you set the parity to None when
communicating with an AdaptaScan Bar Code Reader.